Menu
Blue Sea Systems
  • Products
    • Battery Chargers and Dimmers
      • Battery Chargers
      • USB Chargers
      • Dimmers
    • Automatic Charging Relays
      • m-ACR
      • m-LVD
      • SI-Series
      • BatteryLink
      • ML-ACRs
      • Add-A-Battery Kit
    • Battery Switches
      • Manual Battery Switches
      • Battery Management Panels
      • Remote Battery Switches
    • Solenoids
      • L-Series
      • ML-Solenoids
    • BusBars and Insulators
      • BusBars
      • Terminal Blocks
      • PowerPost Connectors
      • Feed Through Connectors
      • Insulators
      • Cable Clams
    • Fuses and Fuse Blocks
      • Fuses
      • Fuse Holders
      • Fuse Blocks
    • Circuit Breakers
      • Push Button Reset-Only
      • Medium Duty
      • 285-Series
      • 187-Series
      • Klixon
      • A-Series
      • C-Series
      • ELCI and GFCI
      • Mil-Spec
      • Surface Mount System
      • Circuit Breaker Blocks
      • Accessories
    • Panels
      • DC Panels
      • AC Panels
      • ACDC Panels
      • Custom Panels
      • Panel Accessories
      • Labels
    • Meters
      • Analog Meters
      • DIN Meters
      • Digital Meters
      • M2 OLED Digital Monitors
      • Systems Monitors
      • Clamp
      • Shunts
      • Gauges
      • Accessories
    • Switches
      • Contura Switches
      • Toggle Switches
      • Rocker Switches
      • Push Button Switches
      • Rotary Switches
      • Accessories
  • Where to Buy
  • Support
    • Technical Help
      • Articles
      • Reference
      • Documents
    • System Diagrams
    • Marketing Materials
      • Catalog
      • Apparel
      • Merchandising Displays
      • Posters
      • Product Guides
      • Sales Sheets
      • Signage
      • Product & Price Lists
      • Product Images
    • Newsroom
      • Press Room
      • Newsletters
      • News Releases
    • ABYC C7 Compliance
    • Warranty Registration
    • Authorized Internet Reseller Program
  • About Us
  • Circuit Wizard
  • Panel Wizard
  • Order Labels
    • Browse Labels
  • View Catalog

A-Series White Toggle Circuit Breaker - Double Pole 40A

7240
Product Image
Where to Buy TECH Installer Add to Cart
Adding Item to Cart

Features

  • Meets American Boat and Yacht Council (ABYC) standards
  • The industry standard circuit breaker for Blue Sea Systems' electrical panels
  • Combines swtiching and circuit protection into a single device
  • "Trip Free" design cannot be held "ON" during fault current condition

Documents

Installation

jpg fileDimension Drawing

Product Certificates

pdf fileCE Certificate for A-Series Circuit Breakers

Specifications

Amperage40A AC
40A DC
ColorWhite
Actuator Style Toggle
Poles2
Maximum Voltage250V AC
65V DC
Circuit Breaker TypeMagnetic Hydraulic - trip free
Interrupt Capacity 3000A @ 120V AC
3000A @ 240V AC
1500A @ 250V AC [TUV]
3000A @ 250V AC [UL 1077]
7500A @ 65V DC
Minimum Operating Temperature-40° C
Maximum Operating Temperature85° C
Mounting Screw#6-32 Stainless Steel
Mounting Screw Torque6 in-lb (0.68 Nm)
Screw Terminal Torque14 in-lb (1.58 Nm)
Switching Cycles10000
Terminal Screw#10-32 Stainless Steel
Weight0.30lb (0.14 kg)

Regulatory Specifications

CE Marked
CSA certified
TUV certified
UL 1077

Trip Delay Curve

Optional Accessories

8173 A-Series Double Blank Mounting Panel

Similar Products

7200 A-Series Black Toggle Circuit Breaker - Single Pole 5A
7201 A-Series Red Toggle Circuit Breaker - Single Pole 5A
7202 A-Series White Toggle Circuit Breaker - Single Pole 5A
7204 A-Series Black Toggle Circuit Breaker - Single Pole 10A
7205 A-Series Red Toggle Circuit Breaker - Single Pole 10A
7206 A-Series White Toggle Circuit Breaker - Single Pole10A
7208 A-Series Black Toggle Circuit Breaker - Single Pole 15A
7209 A-Series Red Toggle Circuit Breaker - Single Pole 15A
7210 A-Series White Toggle Circuit Breaker - Single Pole 15A
7212 A-Series Black Toggle Circuit Breaker - Single Pole 20A
7213 A-Series Red Toggle Circuit Breaker - Single Pole 20A
7214 A-Series White Toggle Circuit Breaker - Single Pole 20A
7216 A-Series Black Toggle Circuit Breaker - Single Pole 25A
7217 A-Series Red Toggle Circuit Breaker - Single Pole 25A
7218 A-Series White Toggle Circuit Breaker - Single Pole 25A
7220 A-Series Black Toggle Circuit Breaker - Single Pole 30A
7221 A-Series Red Toggle Circuit Breaker - Single Pole 30A
7222 A-Series White Toggle Circuit Breaker - Single Pole 30A
7224 A-Series Black Toggle Circuit Breaker - Single Pole 40A
7225 A-Series Red Toggle Circuit Breaker - Single Pole 40A
7226 A-Series White Toggle Circuit Breaker - Single Pole 40A
7228 A-Series Black Toggle Circuit Breaker - Single Pole 50A
7229 A-Series Red Toggle Circuit Breaker - Single Pole 50A
7230 A-Series White Toggle Circuit Breaker - Single Pole 50A
7232 A-Series Black Toggle Circuit Breaker - Double Pole 10A
7233 A-Series White Toggle Circuit Breaker - Double Pole 10A
7234 A-Series Black Toggle Circuit Breaker - Double Pole 15A
7235 A-Series White Toggle Circuit Breaker - Double Pole 15A
7236 A-Series Black Toggle Circuit Breaker - Double Pole 20A
7237 A-Series Black Toggle Circuit Breaker - Double Pole 30A
7238 A-Series White Toggle Circuit Breaker - Double Pole 30A
7239 A-Series Black Toggle Circuit Breaker - Double Pole 40A
7240 A-Series White Toggle Circuit Breaker - Double Pole 40A
7241 A-Series Black Toggle Circuit Breaker - Double Pole 50A
7242 A-Series White Toggle Circuit Breaker - Double Pole 50A
7260 A-Series White Toggle Circuit Breaker - Double Pole 20A
7294 A-Series White Toggle Circuit Breaker - Double Pole 16A
7295 A-Series White Toggle Circuit Breaker - Double Pole 32A
7299 A-Series White Toggle Circuit Breaker - Single Pole 8A
7347 A-Series Black Toggle Circuit Breaker - Single Pole 8A
7348 A-Series Black Toggle Circuit Breaker - Double Pole 16A
7349 A-Series Black Toggle Circuit Breaker - Single Pole 32A

Frequently Asked Questions

Q: What size CPD (Circuit Protection Device) is required?

A: The short answer is that the CPD (Circuit Protection Device) should be rated to open at an amperage that is greater than the maximum load the circuit will carry and smaller than the rated amperage capacity of the wire in the circuit. We recommend choosing a size as close to, but not greater than, the amperage capacity of the wire.

Use our Circuit Wizard to find what circuit protection would work best for your application.
Q:
What size fuse or circuit breaker do I need?

Q: Are fuses and circuit breakers interchangeable?

A: The short answer is yes. The longer and more accurate answer is more complex and beyond the scope of this discussion. As amperage ratings increase, circuit breakers become relatively more expensive than fuses. Generally, fuses are less expensive for a given rating, but circuit breakers are re-settable and don’t require the purchase of spares, as do fuses. Also, circuit breakers can be used as switches.

Q: How do fuses and circuit breakers differ?

A: Fuses are thermal devices that open the circuit by utilizing a “fusible link” that melts at a known amperage in a known length of time. Circuit breakers can be either thermal or magnetic devices or a combination of the two.

Q: How does the CPD (Circuit Protection Device) stop the amperage flow?

A: There are two primary methods that CPD’s use to determine that excess amperage is flowing in a circuit. Thermal devices open to break the circuit and stop the current flow in response to heat generated by the excess amperage. Magnetic devices react to a magnetic field created by excess amperage.

Q: Why is Opening Speed Important?

A: When a circuit is activated, there is an initial surge of current (amperage) that the CPD must allow to pass without tripping the CPD. The two screen reprints below from the Blue Sea Systems’ testing system illustrate the difference in inrush currents between inductive (like motors) and resistive (like light bulbs) loads.

Notice that the ratio of normal running current (represented by the flat portion of the amperage line) between the inductive and the resistive graphs varies dramatically. The 17A inductive load initially drew 80 A or 470%, whereas the 44A resistive load initially drew only 126A or 286% of its normal operating current. Such inrush currents must be ­considered when sizing CPD’s. Each Blue Sea Systems’ CPD has a time/current chart shown on its catalog page.

We recommend sizing fuses and circuit breakers for 5X multiples for inductive loads and 3X multiples for resistive loads and assuming this inrush for approximately .5 seconds.

Inductive Load
Resitive Load